Sign In | Join Free | My entremaqueros.com
entremaqueros.com
WUXI GLOBAL POWER TECHNOLOGY CO.,LTD
WUXI GLOBAL POWER TECHNOLOGY CO.,LTD User First, Honesty Based; Create GP-brand by Quality, Gain reputation by Service.
Home > Silent Diesel Generator Set >

200 KVA Perkins Super Quiet Diesel Generator Set DeepSea Control Panel with

WUXI GLOBAL POWER TECHNOLOGY CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

200 KVA Perkins Super Quiet Diesel Generator Set DeepSea Control Panel with

Brand Name : Global Power
Model Number : GPP160
Certification : OEM / ISO9001
Place of Origin : Jiangsu, China
MOQ : 1 Set
Price : Negotiable
Supply Ability : 2000 Sets per Year
Delivery Time : 30 working days after received down-payment
Packaging Details : Plastic foam or plywood case packing
Type : Super Silent Type
Prime Power : 200 KVA / 160 KW
Standby Power : 220 KVA / 176KW
Engine : Perkins 1106A-70TAG4
Alternator : Meccalte ECO38-2S4A
Dimensin(L*W*H) : 3500*1500*2300 MM
Weight : 3050 KG
Fuel Tank capacity : 1000 L
Contact Now

Top selling! 200 KVA Perkins Super Silent Diesel Generator Set DeepSea Control Panel with Remote Control


What Are The Benefits Of A Diesel Generator?

Diesel is still the most popular fuel type for portable generators. This is in part due to a number of advantages diesel powered generators have over petrol or gas powered generators.

1. Diesel engines are more fuel efficient that petrol engines. This means longer running time when running at the same capacity. Some diesel engines consume up to half as much fuel as compatible petrol engines.

2. Diesel fuel is cheaper than petrol meaning diesel powered generators are cheaper to run.

3. Diesel powered engines require less maintenance than petrol engines. This is in part due to diesel engines not having spark plugs or carburetors. This means no need to replace spark plugs or rebuild carburetors. The major ongoing service requirement for a diesel engine is regular oil changes.

4. In terms of life span, a diesel engine is much longer lasting. When compared to a typical petrol engine, a diesel engine can last up to 3 times longer.

5. Diesel fuel is safer with less risk of ignition when compared to petrol.

6. Often portable diesel generators are transported on the back of diesel utes. This means you don’t need to have two different fuel types when you’re out and about doing work.



GENERAL DATA
Standby Power L.T.P. (cosØ=0.8)Kva / kW220/ 176
Prime Power P.R.P. (cosØ=0.8)Kva / kW200 / 160
Nominal currentAmps288
Nominal voltageV400 / 230
FrequencyHz50
ENGINEPerkins

1106A-70TAG4

Emission standardEU--
Engine speedrpm1500
Engine governorMechanical / ElectricElectronic
Engine speed regulation%±2%
Cylinder configuration4In line
Cooling typeLiquid / AirLiquid
DisplacementL7
Engine PowerkW202
Battery charging alternator voltageV12
ALTERNATORMeccalteECO38-2S4A
TypeBrushless self exciting, synchronicBrushless self exciting, synchronic
Pole / Connecting type4 / Star Y4 / Star Y
Insulation classHH
Protection gradeIP 23IP 23
Voltage regulation±1.5±1
Waveform distortions THD%≦5%


STANDARD EQUIPMENT:

1. Diesel engine

2. Alternator

3. Starting batteries

4. On engine wiring

5. Fuel tank with on engine fuel installation

6. Elastic engine and alternator mountings

7. Exhaust compensators

8. Silencer

9. On engine liquids (engine oil and cooling liquid, without fuel)

10. Generating set terminal box

11. Main circuit bracer

12. Generating set control panel with engine and alternator parameters indication

13. Emergency stop

14. Acoustic warning signal



ACCESSORY:

1. External fuel tank

2. Synchronization with other generator set

3. Ventilation

4. Exhaust piping systme

5. Different protection

6. Other voltage application

7. Individual ATS

8. Spark arrestor

9. Remote control

10. Maintenance contract

11. others


Energy Saving Measures for DG Sets

a) Ensure steady load conditions on the DG set, and provide cold, dust free air at intake (use of air washers for large sets, in case of dry, hot weather, can be considered).

b) Improve air filtration.

c) Ensure fuel oil storage, handling and preparation as per manufacturers' guidelines/oil com- pany data.

d) Consider fuel oil additives in case they benefit fuel oil properties for DG set usage.

e) Calibrate fuel injection pumps frequently.

f) Ensure compliance with maintenance checklist.

g) Ensure steady load conditions, avoiding fluctuations, imbalance in phases, harmonic loads.

h) In case of a base load operation, consider waste heat recovery system adoption for steam generation or refrigeration chiller unit incorporation. Even the Jacket Cooling Water is amenable for heat recovery, vapour absorption system adoption.

i) In terms of fuel cost economy, consider partial use of biomass gas for generation. Ensure tar removal from the gas for improving availability of the engine in the long run.

j) Consider parallel operation among the DG sets for improved loading and fuel economy thereof.

k) Carryout regular field trials to monitor DG set performance, and maintenance planning as per requirements.


WUXI GLOBAL POWER TECHNOLOGY CO., LTD
Add: E1 Building, No. 20 Dingxiang East Rd, Binhu District, Wuxi,Jiangsu, China
Zip Code: 214161
Tel: 86-510-85748495/13921154615
Email: czh@global-powers.com
Website:www.global-powers.com


Product Tags:

genset silent generator set

      

genset silent portable

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

200 KVA Perkins Super Quiet Diesel Generator Set DeepSea Control Panel with Images

Inquiry Cart 0

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2018 entremaqueros.com. All rights reserved.